M607A11/017AC美国PCB转接头加线缆
M607A11/017AC美国PCB转接头加线缆
Platinum Stock Products; Low profile industrial ICP® accel, 100 mV/g, 0.5 to 10k Hz, side exit, 10-ft integral cable & swiveler base, single point ISO 17025 accredited calibration
US patent number 6.435.902.
Sensitivity: (±15%) 100 mV/g (10.2 mV/(m/s²))
Frequency Range: (±3dB) 30 to 600000 cpm (0.5 to 10000 Hz)
Sensing Element: Ceramic
Measurement Range: ±50 g (±490 m/s²)
Weight: 1.1 oz (31 gm)
PERFORMANCESensitivity (±15 %)100 mV/g10.2 mV/(m/s²)[1] Measurement Range±50 g±490 m/s²Frequency Range (±3 dB)30 to 600000 cpm0.5 to 10000 Hz
Resonant Frequency1500 kcpm25 kHz[3] Broadband Resolution (1 to 10000 Hz)350 µg3434 µm/sec2[3] Non-Linearity±1 %±1 %[2] Transverse Sensitivity≤7 %≤7 %
ENVIRONMENTALOverload Limit (Shock)5000 g pk49050 m/s² pk
Temperature Range-65 to +250 °F-54 to +121 °C
Temperature ResponseSee Graph %/°FSee Graph %/°F[3] Enclosure RatingIP68IP68
ELECTRICALSettling Time (within 1% of bias)≤2 sec≤2 sec
Discharge Time Constant≥0.3 sec≥0.3 sec
Excitation Voltage18 to 28 VDC18 to 28 VDC
Constant Current Excitation2 to 20 mA2 to 20 mA
Output Impedance<150 Ohm<150 Ohm
Output Bias Voltage8 to 12 VDC8 to 12 VDC
Spectral Noise (10 Hz)8 µg/√Hz78.5 (µm/sec2)/√Hz[3] Spectral Noise (100 Hz)5 µg/√Hz49.1 (µm/sec2)/√Hz[3] Spectral Noise (1 kHz)4 µg/√Hz39.2 (µm/sec2)/√Hz[3] Electrical Isolation (Case)>100000000 Ohm>100000000 Ohm
PHYSICALSize - Hex9/16 in14 mm
Size - Height0.97 in24.6 mm
Weight (without cable)1.1 oz31 gm[7] MountingStudStud
Mounting Thread1/4-28 Male1/4-28 Male[5] Mounting Torque (Stud)3 to 4 ft-lb4.1 to 5.4 Nm[6][8] Mounting Torque (hex nut)2 to 3 ft-lb2.7 to 4.1 Nm
Sensing ElementCeramicCeramic
Sensing GeometryShearShear
Housing MaterialStainless SteelStainless Steel
SealingWelded HermeticWelded Hermetic
Electrical ConnectorMolded Integral CableMolded Integral Cable
Electrical Connection PositionSideSide
Cable Length10 ft3.0 m
Cable TypePolyurethanePolyurethane[4]
All specifications are at room temperature unless otherwise specified.
Product Notes
[1] Conversion Factor 1g = 9.81 m/s².
[2] Zero-based, least-squares, straight line method.
[3] Typical.
[4] Twisted shielded pair.
[5] 1/4-28 has no equivalent in S.I. units.
[6] Stud torque must exceed sensor hex nut torque to ensure proper dismantling.
[7] Measured with mounting stud.
[8] 1/8" hex Allen key required for English version, 3mm hex Allen key required for metric version.
[9] See PCB Declaration of Conformance PS023 or PS060 for details.
Accessories:
Supplied080A156Mounting Base(1)ICS-2NIST-traceable single-point amplitude response calibration at 6000 cpm (100 Hz) for each axis(1)
Optional Versions:
(EX) Hazardous Area Approval- contact factory for specific approvals
ENGLISHSI Hazardous Area ApprovalEEx nL IIC T4, -40°C<=Ta<=121°C, II 1 G Hazardous Area ApprovalCl I, Div I, Groups A, B, C, D; Cl II, Div I, Groups E, F, G; Cl III, Div I Hazardous Area ApprovalCl I, Div 2, Groups A, B, C, D; ExnL IIC T4, AExnA IIC T4 Hazardous Area ApprovalEx ia IIC T4, AExia IIC, T4 Hazardous Area ApprovalEEx nL IIC T4, -40°C<=Ta<=121°C, II 3 G
(M) Metric Mount
ENGLISHSI
Accessories:
M080A159AAccessory for IMI Sensors Product(1)
(TO) Temperature Output
ENGLISHSI Temperature Output Range+36 to +250 °F+2 to +121 °C Temperature Scale Factor5.56 mV/°F + 32+10 mV/°C Electrical Connections (White)Temperature Output Electrical Connections (Red)Acceleration Output Electrical Connections (Black)Ground Electrical ConnectorMolded Integral Cable