1380-01A(1631-01C)1631-04C称重传感器大的惊喜
1380-01A(1631-01C)1631-04C称重传感器大的惊喜
1380-01A
PCB L&T Rod End Load Cell, 500 lbf (2.2 kN) rated capacity, 50% static overload protection, 3/4-16 male & female thread, aluminum construction
Measurement Range: 500 lbf (2224 N)
Size - Diameter: 1.50 in (38.1 mm)
Size - Height: 4.25 in (107.9 mm)
Electrical Connector: PT02E-10-6P
Performance | |||
Measurement Range | 500 lbf | 2224 N | [1] |
Sensitivity (±10 %) | 2 mV/V | 2 mV/V | [2] |
Non-Linearity | ≤0.25 % FS | ≤0.25 % FS | |
Hysteresis | ≤0.15 % FS | ≤0.15 % FS | |
Non-Repeatability | ≤0.05 %RO | ≤0.05 %RO | |
Resonant Frequency | 9 kHz | 9 kHz | |
Environmental | |||
Overload Limit | 750 lbf | 3336 N | |
Load Limit (Side Force, FX or FY) | 250 lbf | 1112 N | [3] |
Load Limit (Bending Moment, MX or MY) | 750 inf-lb | 85 Nm | [3] |
Load Limit (Axial Torque, MZ) | 500 inf-lb | 56 Nm | [3] |
Temperature Range (Operating) | -20 to +200 °F | -28 to +93 °C | |
Temperature Range (Compensated) | +70 to +170 °F | +21 to +77 °C | |
Temperature Effect on Output (Maximum) | ±0.01 %Reading/°F | ±0.018 %Reading/°C | [4] |
Temperature Effect on Zero Balance (Maximum) | ±0.005 %FS/°F | ±0.009 %FS/°C | [4] |
Electrical | |||
Bridge Resistance | 350 Ohm | 350 Ohm | [5] |
Excitation Voltage (Recommended) | 10 VDC | 10 VDC | [6] |
Insulation Resistance | >5000000000 Ohm | >5000000000 Ohm | |
Zero Balance | ≤1 % FS | ≤1 % FS | |
Output Polarity | Positive | Positive | |
Output Polarity | +Tension | +Tension | |
Physical | |||
Size - Height | 4.25 in | 107.9 mm | [7] |
Size - Diameter | 1.50 in | 38.1 mm | [7] |
Weight | 0.5 lb | 227 g | |
Mounting Thread | 3/4 - 16 Male | No Metric Equivalent | |
Mounting Thread | 3/4 - 16 Female | No Metric Equivalent | |
Cover Material | Anodized Aluminum | Anodized Aluminum | |
Sensor Material | Anodized Aluminum | Anodized Aluminum | |
Sensing Element | Strain Gage | Strain Gage | |
Deflection at Full Scale Capacity | 0.0004 in | 0.010 mm | |
Electrical Connector | PT02E-10-6P | PT02E-10-6P |
1631-01C
PCB L&T S-Type Load Cell, 500 lbf rated capacity, 150% of RO static overload protection, 2mV/V output, 1/2-20 UNF threads, integral 10 ft cable w/ open end, aluminum construction
Measurement Range: 500 lb (2224 N)
Size - Height: 3.0 in (76.2 mm)
Electrical Connector: 10 ft - Integrated Cable
Performance | |||
Measurement Range | 500 lb | 2224 N | [1] |
Sensitivity (±10 %) | 2 mV/V | 2 mV/V | [2] |
Non-Linearity | ≤0.05 % FS | ≤0.05 % FS | |
Hysteresis | ≤0.03 % FS | ≤0.03 % FS | |
Non-Repeatability | ≤0.02 %RO | ≤0.02 %RO | |
Creep (in 20 minutes) | ≤0.08 % | ≤0.08 % | |
Resonant Frequency | 2.2 kHz | 2.2 kHz | |
Environmental | |||
Overload Limit | 750 lb | 3336 N | |
Load Limit (Side Force, FX or FY) | 50 lb | 222.4 N | [3] |
Load Limit (Bending Moment, MX or MY) | 100 in-lb | 11.3 Nm | [3] |
Load Limit (Axial Torque, MZ) | 100 in-lb | 11.3 Nm | [3] |
Temperature Range (Operating) | 0 to +200 °F | -18 to +93 °C | |
Temperature Range (Compensated) | +70 to +170 °F | +21 to +77 °C | |
Temperature Effect on Output (Maximum) | ±0.0008 %Reading/°F | ±0.0015 %Reading/°C | [4] |
Temperature Effect on Zero Balance (Maximum) | ±0.0015 %FS/°F | ±0.027 %FS/°C | [4] |
Electrical | |||
Bridge Resistance | 350 Ohm | 350 Ohm | [5] |
Excitation Voltage (Recommended) | 10 VDC | 10 VDC | [6] |
Insulation Resistance | >5000000000 Ohm | >5000000000 Ohm | |
Zero Balance | ±1 % FS | ±1 % FS | |
Output Polarity | +Tension | +Tension | |
Physical | |||
Size - Height | 3.0 in | 76.2 mm | |
Size - Width | 1.0 in | 25.4 mm | |
Size - Length | 2.0 in | 51.0 mm | [7] |
Weight | 0.43 lb | 195 g | |
Housing Material | Aluminum | Aluminum | |
Sensing Element | Strain Gage | Strain Gage | |
Deflection at Full Scale Capacity | 0.0025 in | 0.05 mm | |
Electrical Connector | 10 ft - Integrated Cable | 10 ft - Integrated Cable | |
Electrical Connection Position | Side | Side |
1631-04C
PCB L&T S-Type Load Cell, 2,000 lbf rated capacity, 150% of RO static overload protection, 2mV/V output, 1/2-20 UNF threads, integral 10 ft cable w/ open end, nickel-plated steel
Measurement Range: 2000 lb (8896 N)
Size - Height: 3.0 in (76.2 mm)
Electrical Connector: 10 ft - Integrated Cable
Performance | |||
Measurement Range | 2000 lb | 8896 N | [1] |
Sensitivity (±10 %) | 2 mV/V | 2 mV/V | [2] |
Non-Linearity | ≤0.05 % FS | ≤0.05 % FS | |
Hysteresis | ≤0.03 % FS | ≤0.03 % FS | |
Non-Repeatability | ≤0.02 %RO | ≤0.02 %RO | |
Creep (in 20 minutes) | ≤0.08 % | ≤0.08 % | |
Resonant Frequency | 2.4 kHz | 2.4 kHz | |
Environmental | |||
Overload Limit | 3000 lb | 13.3 kN | |
Load Limit (Side Force, FX or FY) | 200 lb | 890 N | [3] |
Load Limit (Bending Moment, MX or MY) | 400 in-lb | 45.2 Nm | [3] |
Load Limit (Axial Torque, MZ) | 400 in-lb | 45.2 Nm | [3] |
Temperature Range (Operating) | 0 to +200 °F | -18 to +93 °C | |
Temperature Range (Compensated) | +70 to +170 °F | +21 to +77 °C | |
Temperature Effect on Output (Maximum) | ±0.0008 %Reading/°F | ±0.0015 %Reading/°C | [4] |
Temperature Effect on Zero Balance (Maximum) | ±0.0015 %FS/°F | ±0.027 %FS/°C | [4] |
Electrical | |||
Bridge Resistance | 350 Ohm | 350 Ohm | [5] |
Excitation Voltage (Recommended) | 10 VDC | 10 VDC | [6] |
Insulation Resistance | >5000000000 Ohm | >5000000000 Ohm | |
Zero Balance | ±1 % FS | ±1 % FS | |
Output Polarity | +Tension | +Tension | |
Physical | |||
Size - Height | 3.0 in | 76.2 mm | |
Size - Width | 1.0 in | 25.4 mm | |
Size - Length | 2.00 in | 51.0 mm | [7] |
Weight | 1.2 lb | 544 g | |
Mounting Thread | 1/2-20 Thread | No Metric Equivalent | |
Housing Material | Nickel Plated Steel | Nickel Plated Steel | |
Sensing Element | Strain Gage | Strain Gage | |
Deflection at Full Scale Capacity | 0.003 in | 0.05 mm | |
Electrical Connector | 10 ft - Integrated Cable | 10 ft - Integrated Cable | |
Electrical Connection Position | Side | Side |
我公司主要经营变频器,纠偏,触摸屏,PLC,伺服,限位开关,传感器,编码器等